Permit Record

Building permit

2600 Independence Ave SE, Washington, DC 20003

ClassificationCONSTRUCTION - MISCELLANEOUS
Reliable valueNot in source
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Sih Nebt; Markos Dereje
Owner
Dc Water Sihjv Nebt
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
RES-343F0000
Climate zone (IECC)
4A
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
MISCELLANEOUS
Geocode & dates
Coordinates
38.8849, -76.9718
Geocode confidence
95%
Geocode source
Not in source
Issued
Sep 4, 2025
Applied
Not in source
Work class
Not in source
Description
Source description

DC Water - DCCR will Abandon thirteen (13) wells out of the 35 wells constructed under permit SB140002. Twelve (12) of the 13 wells available were Approved under Construction Permit SB1400002, which are (E-77,E-78, E-80, INC-25, INC-26, INC-27, INC-33, INC-34, INC-35, INC-38, INC-42 and INC-46); also P2-17A, which was installed without the District's permit. The other 22 wells were not properly maintained hence were destroyed during the DCCR-ART construction operations. ABANDONMENT PROCEDURES FOR THE 13 WELLS YET AVAILABLE: EXTENSOMETERS (E) AND PIEZOMETERS (VWPZ): Over drill Extensometers E-77, E-78, E-80 to 10' bgs; and VWPZ P2-17A to 40' bgs, Tremie grout each of the over drilled boreholes to 2' bgs, then Backfill with same and like material to 0 feet. INCLINOMETERS (INC): Tremie grout the inclinometer casing pipes of INC-25, INC-26, INC-27, INC-33 and INC-38 from 70', 73', 53', 40',125' bgs, respectively, to 0'. INC-34, INC35, INC-42, and INC-46 are blocked at 20', 0', 20' and 0' bgs, respectively; then cannot be grouted so they will be directly overdrilled. Overdrilling inclinometers: INC-27 to 5' bgs, Inclinometers INC-25, INC-26, INC-33 and INC-34 overdrilled to 30' bgs each. Inclinometers INC-35, INC-38, INC-42, INC-46 will be each overdrilled to 40' bgs each. Tremie grout each of the over drilled boreholes to 2' bgs. Backfill with same and like material to 0 feet, as needed. For the 13 wells, site restoration of will follow no later than 24 hrs.

Status
Current status
issued
Source status
PERMIT ISSUED
Provenance
First seen (no changes since)
May 19, 2026 · 00:17 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel
Developer details
Permit #
SB2500085
Canonical ID
243:SB2500085
Source permit ID
SB2500085
Browse Washington, DC permits in the Market Explorer →Pull this permit via /v1/permits →