Permit Record

Building permit

2600 Independence Ave SE, Washington, DC 20003

ClassificationCONSTRUCTION - MISCELLANEOUS
Reliable valueNot in source
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Sihjv Nebt
Owner
Dc Water Sihjv Nebt
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
RES-343F0000
Climate zone (IECC)
4A
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
MISCELLANEOUS
Geocode & dates
Coordinates
38.8849, -76.9718
Geocode confidence
95%
Geocode source
Not in source
Issued
Nov 12, 2024
Applied
Not in source
Work class
Not in source
Description
Source description

Commission of Fine Arts jurisdiction area (Note: New Permit No. SB2500014 is the replacement to No. SB20003552 which has been cancelled in ACAPROD system for it would have taken long time to get the language and address corrected under it.) DC Water- DCCR will abandon Three (3) out of Four (4) wells, which were approved under well construction Permit SB1800190: P-01, OW-01/P-02, and E3-001/P-01A. The fourth well (Extensometer E3-002) was excavated by DCCR during the NEBT construction. A well owner DCW-DCCR explanation letter also signed by SIHJV, explains the situation in the Work Plan of the Approved package attached. The well abandonment detailed procedures are also in the work plan, and summarized are: Extensometers and Piezometers to be abandoned by over drilling to 5' depth, tremie grout borehole to 2' bgs, backfill with same and like material to (0) feet, as needed, and site restoration. Observation well to abandoned by tremie grouting well screen and riser, then over drill 2" PVC well riser to 60' bgs, tremie grout the over-drilled borehole, top off grout to 2' bgs and restore with same and like material to (0) feet, as needed. Site restoration within 24 hrs, for the three wells.

Status
Current status
expired
Source status
EXPIRED
Provenance
First seen (no changes since)
May 19, 2026 · 00:16 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel
Developer details
Permit #
SB2500014
Canonical ID
243:SB2500014
Source permit ID
SB2500014
Browse Washington, DC permits in the Market Explorer →Pull this permit via /v1/permits →