Permit Record

Pool Spa

10740 E Monterey Ave, Mesa, AZ

ClassificationRES - Swimming PoolResidential Pool Construction
Reliable value$70,003
ContractorPresidential Pools
Permit record
Parties
Contractor
Presidential Pools
Applicant
Rider Permit Service
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
505 sq ft
Parcel & enrichment
Parcel APN
31202341
Climate zone (IECC)
2B
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
Swimming Pool
Geocode & dates
Coordinates
33.3696, -111.6024
Geocode confidence
100%
Geocode source
Not in source
Issued
Oct 27, 2021
Applied
Oct 7, 2021
Work class
Residential
Description
Source description

CONSTRUCT A 456 SF SWIMMING POOL & 49 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 89' OF 1-1/2" PE GAS LINE BURIED 18" WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2018 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/23. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS". CODE MODIFICATION APPROVED WITH STIPULATIONS INCLUDE: A) A SCREWED IN PLACE WIRE MESH SCREEN OVER THE OPERABLE WINDOW AREA: B) SCREWED IN “STOPS” (NOT THUMB SCREWS) MAY BE USED TO LIMIT WINDOW OPENINGS NO MORE THAN 4” AND C) A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION.

Status
Current status
issued
Source status
C of C Issued
Finaled
Jul 20, 2022
Provenance
First seen by PermitCore
May 5, 2026 · 09:27 UTC
Last seen
May 15, 2026 · 09:04 UTC
Last changed
May 15, 2026 · 09:04 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

2 permits at this parcel (parcel 31202341) · Aug 16, 2017Oct 27, 2021

  1. Oct 27, 2021This permitPool Spa · Issued$70,003Presidential Pools
  2. Aug 16, 2017BLD2017-04810Pool Spa · Issued$466,448.49Mbi Builders LLC

Full permit history at this parcel · as of Jul 9, 2026.

Other permits by Presidential Pools

Showing up to 12 most-recent permits by this contractor in the indexed window

No other permits by this contractor in the indexed window.
Developer details
Permit #
PMT21-16499
Canonical ID
143:PMT21-16499
Source permit ID
PMT21-16499
Browse Phoenix permits in the Market Explorer →Pull this permit via /v1/permits →