Pool Spa
6923 E Quill St, Mesa, AZ
- Contractor
- California Pools & Landscaping
- Applicant
- Annette Gordon
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- 233 sq ft
- Parcel APN
- 21920572
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Swimming Pool
- Coordinates
- 33.4753, -111.6811
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Jan 22, 2020
- Applied
- Oct 3, 2019
- Work class
- Residential
Source description
233 SQ FT IN-GROUND SWIMMING POOL. NO HEAT, NO SPA. REFERENCE MASTER PLAN # MST19-00383. INSTALL NEW ELECTRICAL LINE: 115 FT OF (2) #10 AND (2) #8 THWN ELECTRICAL WIRE. 1/2" WRAPPED IMC CONDUIT BURIED A MINIMUM OF 6" DEEP OR 1/2" EMT CONDUIT ABOVE GROUND. 30 AMP CIRCUIT BREAKER. INSTALL NEW GAS LINES: [G1] 123 FT OF 3/4" P.E. GAS PIPING FROM METER TO 30K BTU FIRE PIT. [G2]: 5 FT OF 3/4" PE GAS PIPING "T'd" FROM THE 3/4" [123 FT] MAIN LINE TO 30K BTU FIRE BOWL. 128 FT OF #18 YELLOW, INSULATED TRACER WIRE, A MINIMUM OF 18" GROUND COVER. CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. ADDITIONAL APPROVAL WITH STIPULATIONS INCLUDE: A) A SCREWED IN PLACE WIRE MESH SCREEN OVER THE OPERABLE WINDOW AREA: B) SCREWED IN “STOPS”( NOT THUMB SCREWS) MAY BE USED TO LIMIT WINDOW OPENINGS NO MORE THAN 4” AND: C) A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT19-14417. THESE PLANS CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS.
- Current status
- issued
- Source status
- C of C Issued
- Finaled
- Mar 17, 2020
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:04 UTC
- Last changed
- May 15, 2026 · 09:04 UTC
1 of 12 data-quality checks flagged on this permit. Detail below.
- Valuation is placeholder
valuation_usd_is_placeholdervaluation_usd matched a known placeholder (often 0 or 1) used by the source when the real valuation wasn't reported.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Jan 22, 2020This permitPool Spa · IssuedCalifornia Pools & Landscaping
- Aug 7, 2019PMT19-11754New Construction Residential Sf · Issued$267,575.1
Full permit history at this parcel · as of Jul 9, 2026.
Developer details
- Permit #
- PMT19-14417
- Canonical ID
- 143:PMT19-14417
- Source permit ID
- PMT19-14417