Pool Spa
2605 N Val Vista Dr, Mesa, AZ
- Contractor
- Not in source
- Applicant
- Aaron Bair
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- 5,556 sq ft
- Parcel APN
- 14127005P
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Single Family (Detached)
- Coordinates
- 33.4634, -111.7516
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Dec 5, 2018
- Applied
- Dec 5, 2018
- Work class
- Residential
Source description
TRANSFERRED FROM TIDEMARK BLD2016-00348 - FIRE SPRINKLERS DEFERRED (SPRINKLERS REQ THROUGHOUT NEW & EXISTING). DETACHED 2-STORY SFR FULL INTERIOR REMODEL 5060 SF EXISTING LIVABLE: ADDITION TO LIVABLE INCLUDES: 1958 S.F. MAIN FLOOR AND UPPER LIVABLE, AND 1073 S.F. GUEST HOUSE. NON-LIVABLE ADDITION INCLUDES: 899 S.F. COVERED PATIO ADDITION, 1120 S.F. NEW ATTACHED GARAGE AND ADDING TO THIS PERMIT EXISTING 506 S.F. DETACHED STORAGE BUILDING. STUCCO AND BRICK ON 2x6 FRAME CONSTRUCTION W/ R-19 BATT INSULATION AND 1/2" GYPSUM BD ON THE INTERIOR FACE. ASPHALT SHINGLES ON COMMON TRUSSES W/ R-41 (11.25") SPRAYON POLYURETHANE FOAM INSULATION ON THE UNDERSIDE OF ROOF (S) W/ INTUMESCENT COATING IN "ATTIC SPACE" AND R-38 BATT INSULATION ON 1/2" SAG RESISTANT GYPSUM BOARD CEILING. ADDITIONS' NEW ROOF SHALL MATCH EXISTING. NEW 8 CLASS GAS METER (FOR ESTIMATED DEMAND 680 CFH), EXISTING SANITARY ON SEPTIC TANK ** INSPECTOR SEE CASE NOTES **, EXISTING 400 AMPS ELECTRICAL METER TO REMAIN. STRUCTURAL ENGINEER ON RECORD: MICHAEL J KING. REF DEMO PERMIT #BLD2016-00349.REMODEL WORK WILL INCLUDE ELECTRICAL, MECHANICAL, PLUMBING TRADES AND NEW GAS LINE AND METER FOR GAS APPLIANCES.
- Current status
- issued
- Source status
- C of O Issued
- Finaled
- Dec 11, 2018
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:05 UTC
- Last changed
- May 15, 2026 · 09:05 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Dec 5, 2018This permitPool Spa · Issued
- Jan 10, 2017BLD2016-05413Other · FinaledAdobe Fire Protection, LLC
- Apr 13, 2016BLD2016-00348Pool Spa · Issued$300,000
- Jan 20, 2016BLD2016-00349Other · Pending$25,000
Full permit history at this parcel · as of Jul 9, 2026.
Developer details
- Permit #
- PMT18-16701
- Canonical ID
- 143:PMT18-16701
- Source permit ID
- PMT18-16701