Alteration Commercial
111 Massachusetts Ave NW, Washington, DC 20001
- Contractor
- Not in source
- Applicant
- Joseph Jarvis
- Owner
- Gerogetown University
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 0563-0016
- Climate zone (IECC)
- 4A
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- VARIANCE
- Coordinates
- 38.8997, -77.0132
- Geocode confidence
- 95%
- Geocode source
- Not in source
- Issued
- Feb 22, 2024
- Applied
- Not in source
- Work class
- Commercial
Source description
add+alt+rep B2403450 n accordance with Section 104.10 of the Construction Codes (Title 12 of the District of Columbia Municipal Regulations (DCMR)), SmithGroup hereby respectfully requests approval of the proposed modification of the following sections of the Construccion Codes as applied to the above-referenced project/permit. Original code section: DCBC Section 1026.2: The horizontal exit separation shall extend vertically through all levels of the building unless floor assemblies have a fire-resistance rating of not less than two hours with no unprotected openings. Requested modification: Since it is infeasible to provide vertically-aligned horizontal exits or provide two-hour fire ratings for the entire floor assembly, given the existing building conditions, the proposed design includes protecting the existing floor on each side of the horizontal exit for one column bay in both directions. This will provide two-hour fire-rated supporting structure for the horizontal exit and greatly reduce the likelihood of a single fire affecting both sides of the horizontal exit. 1) Are there specific individual reasons that make application of the code impractical? If yes, please explain. a. The exisng floor construction does not meet the indicated design criteria from the original building permit construcon documents. The original construcon documents indicated that the building would meet the construcon requirements for a Type IB building in accordance with the 1972 DC Building Code; this would suggest two-hour rated floor assemblies. Tesng of the exisng floor construcon, including core-drill samples to determine as-built thickness, suggests the actual fire-resistance rang for mulple floors is one hour. This includes several floors that require a horizontal exit in the proposed design. It is impraccal to demolish all exisng floors and replace them with the full two-hour rated construcon. The exisng structure also does not allow the horizontal exit separaon to extend through all levels of the building, making prescripve compliance technically infeasible. 2) Is the requested code modificaon in compliance with the intent and purpose of the Construcon Codes? a. The requested code modificaon follows the intent and purpose of the Construcon Codes. The intent and purpose of a horizontal exit separaon is to allow occupants to move to a safe space in the building where they have addional me for egress from the protected compartment. The purpose of aligning the horizontal exit on all levels when two-hour floor assemblies are not present is to reduce the likelihood of a fire burning to an adjacent floor, compromising the other side of a horizontal exit. By providing a two- hour rang one column bay for the floor assemblies above and below the proposed horizontal exit separaon, the likelihood of a fire burning through the floor on each side of the horizontal exit and effecvely bypassing the horizontal exit is greatly reduced, sasfying the intent of the code. Furthermore, this provides two-hour rated supporng construcon, so that failure of the floor assembly does not cause premature failure of the horizontal exit.
- Current status
- expired
- Source status
- EXPIRED
- First seen (no changes since)
- May 19, 2026 · 00:16 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Aug 6, 2026M2604415MEP Mechanical HVAC · Issued
- Aug 6, 2026E2611637MEP Electrical · Issued
- Aug 6, 2026P2610565MEP Plumbing · Issued
- Aug 5, 2026TL2600056Alteration Commercial · Issued
- Dec 18, 2025P2602799MEP Plumbing · Issued
- Dec 3, 2025E2602782MEP Electrical · Issued
- Nov 25, 2025M2600671MEP Mechanical HVAC · Issued
- Nov 13, 2025E2601839MEP Electrical · Issued
- Oct 24, 2025B2510039Alteration Commercial · Issued
- Sep 4, 2025E2513164MEP Electrical · Finaled
- Aug 12, 2025E2512274MEP Electrical · Finaled
- Aug 7, 2025E2512035MEP Electrical · Finaled
- Jul 30, 2025AH2500969Other · Expired
- Jul 25, 2025P2509556MEP Plumbing · Finaled
- Jun 13, 2025AH2500846Other · Expired
- Jun 9, 2025P2508081MEP Plumbing · Finaled
- Jun 9, 2025M2503406MEP Mechanical HVAC · Finaled
- Jun 4, 2025B2505589Alteration Commercial · Finaled
- May 20, 2025AH2500748Other · Expired
- May 20, 2025AH2500726Other · Expired
- May 20, 2025AH2500749Other · Expired
- Apr 9, 2025AH2500618Other · Expired
- Apr 9, 2025AH2500613Other · Expired
- Mar 24, 2025AH2500548Other · Expired
- Jan 30, 2025AH2500411Other · Expired
- Jan 8, 2025AH2500338Other · Expired
- Dec 18, 2024AH2500306Other · Expired
- Dec 18, 2024AH2500307Other · Expired
- Dec 10, 2024AH2500284Other · Expired
- Nov 26, 2024P2501671MEP Plumbing · Finaled
- Nov 6, 2024AH2500196Other · Expired
- Nov 6, 2024AH2500195Other · Expired
- Oct 16, 2024E2500621MEP Electrical · Finaled
- Oct 15, 2024M2500222MEP Mechanical HVAC · Finaled
- Oct 15, 2024P2500414MEP Plumbing · Expired
- Oct 9, 2024AH2500049Other · Expired
- Oct 9, 2024AH2500054Other · Expired
- Oct 8, 2024E2500309MEP Electrical · Finaled
- Sep 30, 2024P2410611MEP Plumbing · Finaled
- Sep 26, 2024E2413015MEP Electrical · Finaled
- Sep 25, 2024SG2400330Sign · Expired
- Sep 19, 2024E2412722MEP Electrical · Expired
- Sep 19, 2024E2412711MEP Electrical · Issued
- Sep 16, 2024P2410175MEP Plumbing · Finaled
- Sep 16, 2024AH2401049Other · Expired
- Aug 29, 2024E2411844MEP Electrical · Expired
- Aug 23, 2024EA2402381Other · Expired
- Aug 23, 2024B2406347Alteration Commercial · Finaled
- Aug 6, 2024AH2400955Other · Expired
- Aug 1, 2024E2410821MEP Electrical · Expired
- Jul 29, 2024E2410691MEP Electrical · Finaled
- Jul 11, 2024MVQ2400051Alteration Commercial · Expired
- Jul 9, 2024AH2400908Other · Expired
- Jun 19, 2024P2407607MEP Plumbing · Finaled
- Jun 19, 2024M2403335MEP Mechanical HVAC · Finaled
- Jun 17, 2024AH2400833Other · Expired
- Jun 13, 2024E2409054MEP Electrical · Finaled
- Jun 12, 2024B2403450Addition Residential · Finaled
- Jun 6, 2024AH2400785Other · Expired
- Jun 4, 2024AH2400769Other · Expired
- May 13, 2024AH2400710Other · Expired
- Apr 25, 2024SG2400141Sign · Expired
- Apr 9, 2024TC2400005Other · Unknown
- Mar 22, 2024AH2400538Other · Expired
- Mar 22, 2024AH2400539Other · Expired
- Mar 8, 2024B2401792Alteration Commercial · Finaled
- Feb 22, 2024MVQ2400019Alteration Commercial · Expired
- Feb 22, 2024MVQ2400021Alteration Commercial · Expired
- Feb 22, 2024This permitAlteration Commercial · Expired
- Feb 14, 2024AH2400459Other · Expired
- Feb 14, 2024AH2400458Other · Expired
- Jan 16, 2024AH2400363Other · Expired
- Jan 10, 2024AH2400331Other · Expired
- Dec 21, 2023AH2400259Other · Expired
- Dec 11, 2023E2402606MEP Electrical · Finaled
- Nov 14, 2023B2310679Alteration Commercial · Finaled
- Aug 10, 2022F2200729Fence Wall · Expired
- Aug 25, 2017SS1700071Alteration Commercial · Expired
- Apr 28, 2017SS1700030Alteration Commercial · Expired
- Jan 12, 2017ER1700239Other · Expired
- Nov 8, 2016SS1700004Alteration Commercial · Expired
- Jun 6, 2016SS1600056Alteration Commercial · Expired
- May 20, 2016B1608499Alteration Commercial · Issued
- Apr 25, 2016SS1600050Alteration Commercial · Expired
- Nov 18, 2015B1601929Alteration Commercial · Expired
- Nov 10, 2015PC64163433Other · Finaled
- Oct 23, 2015SS1600009Alteration Commercial · Expired
- Nov 21, 2014B1501800Alteration Commercial · Issued
- Oct 10, 2014ER1500082Other · Expired
- Dec 5, 2013AR35946430MEP Mechanical HVAC · Finaled
- Sep 27, 2013E1308892MEP Electrical · Finaled
- Sep 27, 2013E20401992MEP Electrical · Issued
- Sep 16, 2013B1310609Alteration Commercial · Finaled
- May 15, 2013SS1300084Alteration Commercial · Expired
- Mar 15, 2013SS1300049Alteration Commercial · Expired
- Feb 14, 2013AR16555473MEP Mechanical HVAC · Issued
- Jan 10, 2013B1302353Alteration Commercial · Finaled
- Jan 10, 2013E1302268MEP Electrical · Finaled
- Sep 26, 2012SS1200113Alteration Commercial · Expired
- Sep 12, 2012SS1200105Alteration Commercial · Expired
- Feb 8, 2011E1103139MEP Electrical · Issued
- Feb 4, 2011B1103363Alteration Commercial · Issued
- Feb 1, 2011E1102923MEP Electrical · Issued
- Dec 6, 2010B1102122Alteration Commercial · Issued
- Oct 4, 2010B1100060Alteration Commercial · Issued
- May 14, 2010SS1000078Alteration Commercial · Expired
- Aug 13, 2009SS0900087Alteration Commercial · Expired
- Aug 13, 2009SS0900079Alteration Commercial · Expired
- May 15, 2009SS0900057Alteration Commercial · Expired
- Feb 10, 2009E30494194MEP Electrical · Finaled
Full permit history at this parcel · as of Aug 20, 2026.
Developer details
- Permit #
- MVQ2400020
- Canonical ID
- 243:MVQ2400020
- Source permit ID
- MVQ2400020