Commercial
1340 G St NW, Washington, DC 20005
- Contractor
- Not in source
- Applicant
- Anni Balbian
- Owner
- 14th And G Street Holdings LP
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 0253-0054
- Climate zone (IECC)
- 4A
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- MISCELLANEOUS
- Coordinates
- 38.8981, -77.0313
- Geocode confidence
- 95%
- Geocode source
- Not in source
- Issued
- Nov 30, 2017
- Applied
- Not in source
- Work class
- Commercial
Source description
ECS will employ a track-mounted drill rig, which uses continuous flight, hollow-stem augers (HAS) to advance 5 boreholes. The boring will create at 6.5 inch anulus. All 5 borings will be completed to a depth of 50 feet below ground surface. 1 of the borings will be converted into groundwater monitoring well. The well will be constructed of factory cleaned and wrapped 2-inch PVC consisting of 10 feet of pre-packed 0.020-inch machine slot screen with solid riser pipe to surface. Filter sand will be backfilled from the base of the borehole extending to two feet above the screened pre-packed PVC. Two feet of bentonite will then be placed above the sand, and a grout mixture will then be placed using a tremie pipe from the top of the bentonite to the surface. The remaining borings will be tremie grouted from the bottom to top using a mixture of powered bentonite and potable water per DOEE recommendations.
- Current status
- expired
- Source status
- EXPIRED
- First seen (no changes since)
- May 19, 2026 · 00:09 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Nov 30, 2017This permitOther · Expired
- Nov 15, 2013R1300077Alteration Commercial · Expired
- Aug 21, 2013P1307335MEP Plumbing · Finaled
Full permit history at this parcel · as of Jul 8, 2026.
Developer details
- Permit #
- SB1800064
- Canonical ID
- 243:SB1800064
- Source permit ID
- SB1800064