Alteration Residential
3508 Lynchester Rd, Baltimore, MD
- Contractor
- Not in source
- Applicant
- Not in source
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 3118C026
- Climate zone (IECC)
- 4A
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- 1-09
- Coordinates
- 39.3262, -76.6696
- Geocode confidence
- 100%
- Geocode source
- geocodio
- Issued
- Feb 6, 2024
- Applied
- Not in source
- Work class
- Residential
Source description
LOAN GRANT - NON STRUCTURAL ALTERATIONS - ROOF OVER REAR BUMP OUT WILL BE STRIPED DOWN TO THE DECK. INSTALL WATERPROOF BASE SHEET, DRIP EDGE AND SHINGLES. METAL FLASHING WILL BE INSTALLED ON THE WALL.REMOVE GUTTERS AND DOWNSPOUT INSTALL NEW 5° K STYLE GUTTERS AND DOWNSPOUTS.FRAME AND INSTALL ROOF OVER BASEMENT STEPS. INSTALL BASE SHEET AND SHINGLES ON DECK OF ROOF. (OWNER CHOICE OF COLOR OF SHINGLES.) REAR BUMP OUT (INTERIOR) REWIRE LIGHTS AND REWIRE AND INSTALL NEW RECEPTACLES. 25 FIXTURES/DEVICES INSULATE THE ROOM WITH R21 IN WALLS AND R49 IN CEILING; INSTALL NEW SHEET ROCK AND FINISH. APPLY 1 COAT OF PRIMER AND 2 COATS OF PAINT. INSTALL LAMINATE FLOORING INSTALL DRAIN IN BOTTOM OF BASEMENT STAIRWELL; INSTALL SUMP PUMP IN BASEMENT BASEMENT W/DRAINPIPE HOOKED UP TO WELL, DISCHARGING AND DIVERTING WATER TO THE OUTSIDE OF HOUSE. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE************** AS PER CHAP ATP: NON-STRUCTURAL ALTERATIONS, THE PROPOSED MODIFICATIONS TO THE REAR OF THE HOUSE INVOLVE A COMPREHENSIVE APPROACH TO ENHANCE BOTH FUNCTIONALITY AND AESTHETICS. THE OUTLINED PLAN INCLUDES: 1. ROOF OVER REAR BUMP OUT: STRIPPING DOWN THE EXISTING ROOF TO THE DECK. INSTALLATION OF A WATERPROOF BASE SHEET, DRIP EDGE, AND SHINGLES. ADDITION OF METAL FLASHING ON THE WALL FOR INCREASED WEATHER RESISTANCE. 2. GUTTER AND DOWNSPOUT REPLACEMENT: REMOVAL OF EXISTING GUTTERS AND DOWNSPOUTS. INSTALLATION OF NEW 5° K-STYLE GUTTERS AND DOWNSPOUTS. 3. BASEMENT STEPS ROOF: FRAMING AND INSTALLATION OF A ROOF OVER THE BASEMENT STEPS. INSTALLATION OF BASE SHEET AND SHINGLES ON THE ROOF DECK. 4. INTERIOR RENOVATIONS: REWIRING OF LIGHTS AND INSTALLATION OF NEW RECEPTACLES IN THE REAR BUMP-OUT INTERIOR. INSULATION WITH R21 IN WALLS AND R49 IN THE CEILING. INSTALLATION OF NEW SHEETROCK AND FINISHING. APPLICATION OF ONE COAT OF PRIMER AND TWO COATS OF PAINT. 5. FLOORING INSTALLATION: INSTALLATION OF LAMINATE FLOORING. 6. BASEMENT WATERPROOFING: INSTALLATION OF A DRAIN IN THE BOTTOM OF THE BASEMENT STAIRWELL. INSTALLATION OF A SUMP PUMP IN THE BASEMENT WITH A DRAINPIPE CONNECTED TO THE WELL, DISCHARGING AND DIVERTING WATER TO THE OUTSIDE OF THE HOUSE. ALL WORK TO MATCH PLANS/INFORMATION/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES IT.
- Current status
- issued
- Source status
- Issued
- Expired
- Aug 6, 2024
- First seen by PermitCore
- May 20, 2026 · 02:41 UTC
- Last seen
- Jun 25, 2026 · 01:04 UTC
- Last changed
- Jun 25, 2026 · 01:04 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Feb 6, 2024This permitAlteration Residential · Issued$24,300
- Dec 13, 2021baltimore_COM2021-87980MEP Mechanical HVAC · Issued$16,000
Full permit history at this parcel · as of Jul 8, 2026.
Developer details
- Permit #
- baltimore_COM2023-90771
- Canonical ID
- 337:baltimore_COM2023-90771
- Source permit ID