Permit Record

Pool Spa

1157 N Ellsworth Rd, Mesa, AZ

ClassificationCOM - Com (OTH) -- AdditionsCommercial Pool Construction
Reliable value$125,000
Permit record
Parties
Contractor
Bob'S Air CO
Applicant
Richard, Marston
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
2,500 sq ft
Parcel & enrichment
Parcel APN
22019007 E
Climate zone (IECC)
2B
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
Com (OTH) -- Additions
Geocode & dates
Coordinates
33.4365, -111.6308
Geocode confidence
100%
Geocode source
Not in source
Issued
Aug 8, 2005
Applied
Apr 25, 2005
Work class
Commercial
Description
Source description

Build out 2,500 sq. ft. of shell space for restaurant. Existing building has CMU exterior walls with wood roof. Work includes steel stud and gyp-board interior walls. Gyp-board ceilings in rest rooms and janitors closet with T-bar ceiling throughout balance of space, kitchen has vinyl-faced panels. Two ADA accessible rest rooms, men's room has water closet, urinal and lavatory, women's room has water closet and lavatory. Installation of sanitary waste system and grease waste system with 2,500-gallon grease interceptor. Installation of potable hot and cold water system with all associated piping, fixtures and fittings. Installation of low-pressure natural gas system (1,563 CFH) for cooking, heating and water heater. Installation of one additional rooftop heat pump (6.25-Ton, 2,400 CFM, 1,099 lbs operating weight) with smoke detector and all associated ductwork and grills. Installation of two Type I hoods (hood one 3,800 CFM - xxx lbs. Operating weight, hood two 1,700 CFM - xxx lbs. Operating weight) with make up air unit (5,500 CFM - xxx lbs. Operating weight), one Type II hood (560 CFM - xxx lbs. Operating weight) and two 215 CFM bath exhaust fans. Building has 1,000 A 120/208V, 3PH, 4W, SES with One 100A House Panel with all associated wiring for building lights and power. Install two 200A Sub Panels with all associated wiring for lights and power. Install 2-1/2" low pressure gas meter with all distribution piping for cooking and heating equipment. -- Applicant has elected to defer the following fire protection systems: HOOD EXTINGUISHING SYSTEM. Installation of deferred submittal systems is not permitted until plans have been approved and issued. No Certificate of Occupancy, Certificate of Compliance, or Building Final will be granted until such systems are approved and pass final inspection. Applicant is solely responsible for securing such permits in a timely fashion in accord with their construction schedule.

Status
Current status
issued
Source status
Issued
Provenance
First seen by PermitCore
May 5, 2026 · 09:26 UTC
Last seen
May 15, 2026 · 09:03 UTC
Last changed
May 15, 2026 · 09:03 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel
Other permits by Bob'S Air CO

Showing up to 12 most-recent permits by this contractor in the indexed window

No other permits by this contractor in the indexed window.
Developer details
Permit #
BLD2005-04181
Canonical ID
143:BLD2005-04181
Source permit ID
BLD2005-04181
Browse Phoenix permits in the Market Explorer →Pull this permit via /v1/permits →