Permit Record

Pool Spa

9918 E Rotation Dr, Mesa, AZ

ClassificationRES - Swimming PoolResidential Pool Construction
Reliable value$34,000
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Sean Beavers
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
418 sq ft
Parcel & enrichment
Parcel APN
31328021
Climate zone (IECC)
2B
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
Swimming Pool
Geocode & dates
Coordinates
33.3363, -111.6200
Geocode confidence
100%
Geocode source
Not in source
Issued
Jul 15, 2021
Applied
Jun 28, 2021
Work class
Residential
Description
Source description

CONSTRUCT A 418 SQ FT IN-GROUND SWIMMING POOL. REFERENCE MASTER PLAN # MST19-00383. I45 FT OF 3/4" 3/4" WRAPPED IMC A MINIMUM OF 6" GROUND COVER OR 3/4" EMT, (2) #6, (2) #10) THWN WIRES FROM MAIN PANEL TO SUB PANEL. 50 AMP CIRCUIT BREAKER. INSTALL NEW GAS LINE: 140 FT OF 2" PE GAS PIPING, #18 TRACER WIRE FROM METER TO 500K BTU POOL HEATER. A MINIMUM OF 18" GROUND COVER. INSTALLATION OF GAS LINE(S) SHALL BE IN COMPLIANCE WITH 2018 IFGC AND SW GAS SPECIFICATIONS. CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. ADDITIONAL APPROVAL WITH STIPULATIONS INCLUDES A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT21-11022 THESE PLANS SHALL CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS.

Status
Current status
issued
Source status
C of C Issued
Finaled
Jul 18, 2022
Provenance
First seen by PermitCore
May 5, 2026 · 09:27 UTC
Last seen
May 15, 2026 · 09:04 UTC
Last changed
May 15, 2026 · 09:04 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

2 permits at this parcel (parcel 31328021) · Oct 19, 2020Jul 15, 2021

  1. Jul 15, 2021This permitPool Spa · Issued$34,000
  2. Oct 19, 2020PMT20-15492New Construction Residential Sf · Issued$628,770.87Woodside Homes Of Arizona

Full permit history at this parcel · as of Aug 11, 2026.

Developer details
Permit #
PMT21-11022
Canonical ID
143:PMT21-11022
Source permit ID
PMT21-11022
Browse Phoenix permits in the Market Explorer →Pull this permit via /v1/permits →