Permit Record

Pool Spa

10562 E Mendoza Ave, Mesa, AZ

ClassificationRES - Swimming PoolResidential Pool Construction
Reliable value$50,000
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Arvayo Abraham/jamie L
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
461 sq ft
Parcel & enrichment
Parcel APN
31202277
Climate zone (IECC)
2B
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
Swimming Pool
Geocode & dates
Coordinates
33.3704, -111.6059
Geocode confidence
100%
Geocode source
Not in source
Issued
May 5, 2020
Applied
Mar 24, 2020
Work class
Residential
Description
Source description

CONSTRUCT A 425 SQ FT IN-GROUND SWIMMING POOL AND 36 SQ FT SPA. INSTALL NEW ELECTRICAL LINE: 75 FT OF 3/4" RIGID PVC, (2) #10, (2) #12 THHN ELECTRICAL WIRE FROM MAIN PANEL TO SUB PANEL AT POOL EQUIPMENT. 30 AMP CIRCUIT BREAKER. INSTALL NEW GAS LINE: 75 FT OF 1 1/4" PE GAS PIPING. #18 TRACER WIRE. A MINIMUM OF 18" GROUND COVER. THESE PLANS CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS. ADDENDA PMT20-05118A: CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. ADDITIONAL APPROVAL WITH STIPULATIONS INCLUDES A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT20-05118A

Status
Current status
finaled
Source status
Finaled – C of O Required
Finaled
Jun 26, 2020
Provenance
First seen by PermitCore
May 5, 2026 · 09:27 UTC
Last seen
May 15, 2026 · 09:04 UTC
Last changed
May 15, 2026 · 09:04 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

2 permits at this parcel (parcel 31202277) · Jun 9, 2016May 5, 2020

  1. May 5, 2020This permitPool Spa · Finaled$50,000
  2. Jun 9, 2016BLD2016-03686New Construction Residential Sf · Finaled$466,602.34Mbi Builders LLC

Full permit history at this parcel · as of Aug 11, 2026.

Developer details
Permit #
PMT20-05118
Canonical ID
143:PMT20-05118
Source permit ID
PMT20-05118
Browse Phoenix permits in the Market Explorer →Pull this permit via /v1/permits →