Pool Spa
10650 E Palladium Dr, Mesa, AZ
- Contractor
- Presidential Pools
- Applicant
- Rider Permit Service
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- 310 sq ft
- Parcel APN
- 30494348
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Swimming Pool
- Coordinates
- 33.3326, -111.6036
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Dec 13, 2021
- Applied
- Nov 19, 2021
- Work class
- Residential
Source description
CONSTRUCT A 310 SQ FT IN-GROUND POOL. NO SPA. REFERENCE MASTER PLAN # MST18-00383. INSTALL NEW ELECTRICAL LINE: 98 FT OF 1/2" PVC CONDUIT #10 THWN WIRE FROM MAIN PANEL TO SUB PANEL. A MINIMUM OF 18" GROUND COVER. 30 AMP CIRCUIT BREAKER. INSTALL NEW GAS LINES: [G1] 97 FT OF 1 1/2" PE GAS PIPE FROM METER TO 400K BTU POOL HEATER. [G2] 28 FT OF 3/4" PE GAS PIPE T'D FROM POOL HEATER TO 75K PIRE PIT. ALLL GAS LINES TO HAVE #18 TRACER WIRE AND A MINIMUM OF 18" GROUND COVER. INSTALLATION TO COMPLY WITH 2018 IFGC AND SW GAS SPECIFICATIONS. CODE MODIFICATION – APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF, SECTION 305.4 #1 OF THE INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) WHICH REQUIRES THAT: SECTION 305.4 #1 OPERABLE WINDOWS HAVING A SILL HEIGHT OF LESS THAN 48” ABOVE THE INDOOR FINISHED FLOOR AND DOORS SHALL HAVE AN ALARM THAT PRODUCES AN AUDIBLE WARNING WHEN THE WINDOW OR THEIR SCREENS ARE OPENED…”THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. APPROVAL WITH CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES STIPULATIONS WHICH INCLUDES A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT21-19096. THESE PLANS SHALL CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS.
- Current status
- issued
- Source status
- C of C Issued
- Finaled
- Jun 8, 2022
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:04 UTC
- Last changed
- May 15, 2026 · 09:04 UTC
1 of 12 data-quality checks flagged on this permit. Detail below.
- Valuation is placeholder
valuation_usd_is_placeholdervaluation_usd matched a known placeholder (often 0 or 1) used by the source when the real valuation wasn't reported.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Dec 13, 2021This permitPool Spa · IssuedPresidential Pools
- Apr 10, 2017BLD2017-02351New Construction Residential Sf · Issued$325,558.47Hsp Arizona INC
Full permit history at this parcel · as of Aug 11, 2026.
Developer details
- Permit #
- PMT21-19096
- Canonical ID
- 143:PMT21-19096
- Source permit ID
- PMT21-19096