Permit Record

Pool Spa

5138 S Curie Way, Mesa, AZ

ClassificationRES - Swimming PoolResidential Pool Construction
Reliable value$45,000
ContractorBluewave Pools
Permit record
Parties
Contractor
Bluewave Pools
Applicant
Annette Gordon
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
30450681
Climate zone (IECC)
2B
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
Swimming Pool
Geocode & dates
Coordinates
33.3221, -111.6141
Geocode confidence
100%
Geocode source
Not in source
Issued
Apr 26, 2022
Applied
Apr 11, 2022
Work class
Residential
Description
Source description

CONSTRUCT A 477 SQ FT IN-GROUND SWIMMING POOL. NO GAS, NO HEAT, NO SPA. REFERENCE MASTER PLAN # MST19-00383. INSTALL NEW ELECTRICAL LINE: 150 FT OF 1/2" WRAPPED IMC CONDUIT, #10 THWN FROM MAIN PANEL TO 30 AMP SUB PANEL. A MINIMUM OF 6" GROUND COVER. CODE MODIFICATION – APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF, SECTION 305.4 #1 OF THE INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) WHICH REQUIRES THAT: SECTION 305.4 #1 OPERABLE WINDOWS HAVING A SILL HEIGHT OF LESS THAN 48” ABOVE THE INDOOR FINISHED FLOOR AND DOORS SHALL HAVE AN ALARM THAT PRODUCES AN AUDIBLE WARNING WHEN THE WINDOW OR THEIR SCREENS ARE OPENED…”THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. APPROVAL WITH CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES STIPULATIONS WHICH INCLUDES A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT22-06447. THESE PLANS SHALL CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS.

Status
Current status
issued
Source status
C of C Issued
Finaled
Oct 17, 2022
Provenance
First seen by PermitCore
May 5, 2026 · 09:27 UTC
Last seen
May 15, 2026 · 09:04 UTC
Last changed
May 15, 2026 · 09:04 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

2 permits at this parcel (parcel 30450681) · Nov 20, 2014Apr 26, 2022

  1. Apr 26, 2022This permitPool Spa · Issued$45,000Bluewave Pools
  2. Nov 20, 2014BLD2014-05852New Construction Residential Sf · Finaled$226,116.48Mattamy Arizona Construction, LLC

Full permit history at this parcel · as of Jul 9, 2026.

Other permits by Bluewave Pools

Showing up to 12 most-recent permits by this contractor in the indexed window

No other permits by this contractor in the indexed window.
Developer details
Permit #
PMT22-06447
Canonical ID
143:PMT22-06447
Source permit ID
PMT22-06447
Browse Phoenix permits in the Market Explorer →Pull this permit via /v1/permits →