Pool Spa
5029 S Cambium Ln, Mesa, AZ
- Contractor
- Not in source
- Applicant
- Sam Lee
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 30450199
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Swimming Pool
- Coordinates
- 33.3242, -111.6070
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Mar 26, 2021
- Applied
- Feb 21, 2021
- Work class
- Residential
Source description
CONSTRUCT A 529 SQ FT IN-GROUND SWIMMING POOL AND 49 SQ FT SPA. REFERENCE MASTER PLAN # MST19-00383. INSTALL NEW ELECTRICAL LINE: [E1] 97 FT OF 3/4" DOUBLE-WRAPPED IMC CONDUIT, (3) #10, (1) #8) THWN WIRE FROM MAIN PANEL TO SUB PANEL. A MINIMUM OF 6" GROUND COVER. 20 AMP CIRCUIT BREAKER. [E2] 51 FT OF 3/4" IMC CONDUIT TO GFCI ELECTRICAL OUTLET. A MINIMUM OF 6" GROUND COVER. ALL ELECTRICAL TO BE INSTALLED PER 2017 NEC AND SRP SPECIFICATIONS. INSTALL NEW GAS LINES: [G1] 97 FT OF 2" PE GAS PIPE, #12 YELLOW, INSULATED TRACER WIRE FROM METER TO 400K BTU HEATER. [G2] 40 FT OF 1" PE GAS PIPE, #12 YELLOW INSULATED TRACER WIRE FROM HEATER TO 60K BBQ. [G3] 18 FT OF 1" PE GAS PIPE T'D OFF OF 1" LINE TO BBQ TO A 90K BTU FIRE PIT. ALL GAS LINES TO BE A MINIMUM OF 18" GROUND COVER. INSTALLATION TO BE IN COMPLIANCE WITH 2018 IFGC AND SW GAS SPECIFICATIONS. CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. ADDITIONAL APPROVAL WITH STIPULATIONS INCLUDES A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT21-03000. THESE PLANS SHALL CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS.
- Current status
- issued
- Source status
- C of C Issued
- Finaled
- Nov 22, 2021
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:04 UTC
- Last changed
- May 15, 2026 · 09:04 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Mar 26, 2021This permitPool Spa · Issued$84,000
- Mar 13, 2013BLD2013-00971New Construction Residential Sf · Finaled$430,028.79Hsp Arizona INC
- Date not in sourcePMT26-15011MEP Plumbing · Pending
Full permit history at this parcel · as of Aug 17, 2026.
Developer details
- Permit #
- PMT21-03000
- Canonical ID
- 143:PMT21-03000
- Source permit ID
- PMT21-03000