Pool Spa
5324 S Sabrina, Mesa, AZ
- Contractor
- Presidential Pools
- Applicant
- Annette Gordon
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- 604 sq ft
- Parcel APN
- 30435545
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Swimming Pool
- Coordinates
- 33.3185, -111.6069
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Sep 30, 2019
- Applied
- Sep 12, 2019
- Work class
- Residential
Source description
CONSTRUCT A 540 SQ FT IN-GROUND POOL & 64 SQ FT SPA WITH NATURAL GAS HEAT. INSTALLATION OF 100' OF 2" PE GASLINE FROM GAS METER TO 400K BTU POOL HEATER, 2' OF 3/4" PE GASLINE TO (3) 75K BTU FIRE BAR, 68' OF 1-1/2" PE GASLINE TO 75K BTU FIREPIT, ALL TO BE INSTALLED A MIN OF 18" WITH 18 GAUGE TRACER WIRE AND PER 2018 IFGC & SW GAS REQUIREMENTS. SW GAS AREA METER MAY NEED TO BE UPGRADED. ELECTRICAL TO BE INSTALLED PER 2017 NEC. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS" CODE MODIFICATION - APPEAL IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. ADDITIONAL APPROVAL WITH STIPULATIONS INCLUDE: A) A SCREWED IN PLACE WIRE MESH SCREEN OVER THE OPERABLE WINDOW AREA: B) SCREWED IN “STOPS”( NOT THUMB SCREWS) MAY BE USED TO LIMIT WINDOW OPENINGS NO MORE THAN 4” AND: C) A LATCHING DEVICE NOT LESS THAN 54” ABOVE THE FLOOR. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION.
- Current status
- issued
- Source status
- C of C Issued
- Finaled
- Mar 16, 2020
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:04 UTC
- Last changed
- May 15, 2026 · 09:04 UTC
1 of 12 data-quality checks flagged on this permit. Detail below.
- Valuation is placeholder
valuation_usd_is_placeholdervaluation_usd matched a known placeholder (often 0 or 1) used by the source when the real valuation wasn't reported.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Sep 30, 2019This permitPool Spa · IssuedPresidential Pools
- Apr 15, 2019PMT19-04596New Construction Residential Sf · Issued$504,198.6Richmond American Homes
Full permit history at this parcel · as of Aug 11, 2026.
Developer details
- Permit #
- PMT19-13611
- Canonical ID
- 143:PMT19-13611
- Source permit ID
- PMT19-13611