Pool Spa
10228 E Thornton Ave, Mesa, AZ
- Contractor
- North Star Pools LLC
- Applicant
- North Star Pools
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- 390 sq ft
- Parcel APN
- 30435396
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Swimming Pool
- Coordinates
- 33.3189, -111.6129
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Mar 25, 2020
- Applied
- Feb 10, 2020
- Work class
- Residential
Source description
CONSTRUCT A 390 SQ FT IN-GROUND SWIMMING POOL. NO SPA. REFERENCE MASTER PLAN # MST19-00383. INSTALL NEW ELECTRICAL LINE: 140 FT OF #10 THHN/THWN ELECTRICAL WIRE AND 1/2" RIGID CONDUIT FROM MAIN PANEL TO SUB PANEL AT POOL EQUIPMENT. 30 AMP CIRCUIT BREAKER. INSTALL NEW GAS LINES: [G1] 100 FT OF 1 1/2" PE GAS PIPE WITH #14 TRACER WIRE FROM METER TO 120K BTU BBQ.. A MINIMUM OF 18" GROUND COVER. [G2] 20 FT OF 3/4" PE GAS PIPING T'd OFF OF THE 1 1/2" GAS LINE TO 80K BTU FIRE PIT. #14 TRACER WIRE. A MINIMUM OF 18" GROUND COVER CODE MODIFICATION - APPEAL WAS HEREBY MADE TO THE BUILDING OFFICIAL FOR A MODIFICATION FROM, OR INTERPRETATION OF SECTION: ISPSC 305.4 OF THE 2018 IRC WITH MESA AMENDMENTS, WHICH REQUIRES THAT AN ALARM, COMPLIANT WITH 2017 UL REQUIREMENTS BE PROVIDED AS BARRIER WHEN WINDOWS OF A DWELLING OR STRUCTURE SERVE AS PART OF THE BARRIER AND WHERE DOORS AND/OR WINDOWS PROVIDE DIRECT ACCESS TO THE POOL/SPA THROUGH THAT WALL. ADDITIONAL APPROVAL WITH STIPULATIONS INCLUDE: SCREWED IN “STOPS” (NOT THUMB SCREWS) MAY BE USED TO LIMIT WINDOW OPENINGS NO MORE THAN 4”. EMERGENCY ESCAPE WINDOWS MAY HAVE AN ALARM OR A LATCHING DEVICE NOT LESS THAT 54” ABOVE THE FLOOR. HOMEOWNER SHALL NOT CHANGE OR MODIFY THE BARRIER IN ANY WAY WITHOUT APPROVAL OF THE BUILDING OFFICIAL. HOMEOWNERS SHALL INFORM FUTURE OWNER OF THE CONDITIONS OF THIS CODE MODIFICATION. REF: POOL PERMIT PMT20-02463 .THESE PLANS CONFORM TO THE REQUIREMENTS OF 2018 ISPSC AND THE MESA RESIDENTIAL CODE WITH ALL CITY OF MESA AMENDMENTS.
- Current status
- issued
- Source status
- C of C Issued
- Finaled
- Jun 1, 2020
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:04 UTC
- Last changed
- May 15, 2026 · 09:04 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Mar 25, 2020This permitPool Spa · Issued$45,000North Star Pools LLC
- Apr 30, 2019PMT19-06143New Construction Residential Sf · Issued$417,527.37Taylor Morrison/arizona INC
Full permit history at this parcel · as of Aug 11, 2026.
Developer details
- Permit #
- PMT20-02463
- Canonical ID
- 143:PMT20-02463
- Source permit ID
- PMT20-02463