Commercial
3657 S Power Rd, Mesa, AZ
- Contractor
- Not in source
- Applicant
- The Commons LLC
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- 9,627 sq ft
- Parcel APN
- 30417001J
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Com (PJT) -- Commercial Buildings
- Coordinates
- 33.3492, -111.6868
- Geocode confidence
- 89%
- Geocode source
- geocodio
- Issued
- Not in source
- Applied
- Sep 25, 2008
- Work class
- Commercial
Source description
Construct 7,501 sq. ft. 5 suite retail building with 2,126 sq. ft. of attached canopies with Site work including public utilities. Offsite improvements broken out into a separate plan set reference BLD2008-09929. Suites 101 thru 104 are finished suites; Suite 105 is a bare shell, SEE CASE NOTES FOR SUITE AREAS. Building has CMU exterior walls with wood framing and prefab roof trusses and 3 coat stucco finish. Install five 5-Ton (2,000 CFM, 745 lbs. operating weight)rooftop heat pumps, two on Suite 101, one each on Suites 102-104 and, install two roof curbs for up to 6-Ton rooftop HVAC unite (max 750 lbs. ea.) on Suite 105. Install 800A 120/208V 3Phase 4Wire SES with one 200A House Panel for general building lights and power, five 200A Panels, on in each suite, and three 200A disconnects for future panels. Install all conduit and wire for lights and power in each of the finished suites. Install one ADA accessible restroom with Insta-Hot water heater and drinking fountain in each of the finished suites. Install 2" water service with a 1-1/2" meter and 4" sanitary sewer service for the building and a 2" Master Site landscape water service and meter. Install 2" water service for future 1" meter for potential Restaurant in Suite 105.
- Current status
- issued
- Source status
- Approved
- First seen by PermitCore
- May 5, 2026 · 09:26 UTC
- Last seen
- May 15, 2026 · 09:02 UTC
- Last changed
- May 5, 2026 · 09:26 UTC
1 of 12 data-quality checks flagged on this permit. Detail below.
- Valuation is placeholder
valuation_usd_is_placeholdervaluation_usd matched a known placeholder (often 0 or 1) used by the source when the real valuation wasn't reported.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Date not in sourceThis permitOther · Issued
- Date not in sourceBLD2003-00404Other · Issued
Full permit history at this parcel · as of Aug 11, 2026.
Developer details
- Permit #
- BLD2008-08878
- Canonical ID
- 143:BLD2008-08878
- Source permit ID
- BLD2008-08878