Demolition
124 N 67th St 122, Mesa, AZ
- Contractor
- Not in source
- Applicant
- Ron Djordjeuvch
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 14159005K
- Climate zone (IECC)
- 2B
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- Renovations/Remodels
- Coordinates
- 33.4180, -111.6875
- Geocode confidence
- 100%
- Geocode source
- Not in source
- Issued
- Nov 3, 2025
- Applied
- Oct 21, 2025
- Work class
- Residential
Source description
The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 10/20/2025 ADDRESS: 124 N 67TH ST 122 MESA DAMAGE CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. A completed Contractor Verification Form must also be submitted prior to being issued a permit This structure is to be restored like for like in compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: Structural members were damaged and will need replacing and/or repairing. Electrical sustained damage to several home runs, panel may not need to be replaced unless it can?t accommodate the requirements needed to comply with 2018 IRC/IBC and/or 2017 NEC. All damaged wires must be replaced per 2017 NEC/2018 IRC. Mechanical equipment was damaged, and all mechanical components will need replacing. Plumbing does not appear to be damaged, however it will need to be inspected during frame inspection Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and mechanical systems damaged by heat are to be replaced. A. Building is: Commercial B. Building permits and inspections are required for the following phase(s) of construction: 1. Structural Yes 2 Electrical Yes 3. Mechanical Yes 4. Plumbing Yes 5. Construction Plans Required No Electrical service can be restored under the following conditions: Electric may be restored during restoration, however if a permit is not obtained and/or repairs have not started within 45 days, the City of Mesa reserves the right to remo
- Current status
- issued
- Source status
- Issued
- Finaled
- Nov 3, 2025
- First seen by PermitCore
- May 5, 2026 · 09:27 UTC
- Last seen
- May 15, 2026 · 09:04 UTC
- Last changed
- May 15, 2026 · 09:04 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Nov 3, 2025This permitDemolition · Issued$12,564
- Aug 14, 2013BLD2013-03912Alteration Commercial · Finaled
- Sep 19, 2008BLD2008-08203Pool Spa · Issued$2,000Kosovo Construction
- Date not in sourceBLD2008-06513New Construction Residential Mf · Finaled
Full permit history at this parcel · as of Aug 11, 2026.
Developer details
- Permit #
- PMT25-19227
- Canonical ID
- 143:PMT25-19227
- Source permit ID
- PMT25-19227