Alteration Commercial
333 G St NW, Washington, DC 20001
- Contractor
- Not in source
- Applicant
- Kim Mitchell
- Owner
- Quadrum Dc LLC
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 0529-0854
- Climate zone (IECC)
- 4A
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- Not in source
- Building subtype
- ALTERATION AND REPAIR
- Coordinates
- 38.8986, -77.0157
- Geocode confidence
- 95%
- Geocode source
- Not in source
- Issued
- Nov 22, 2024
- Applied
- Not in source
- Work class
- Commercial
Source description
Narrative for Permit B2201730 Revision: 1.1 Restaurant fit out. This revision includes the restaurant layout and depicts the ground floor retail being eliminated. The previously approved plans included two bars, kitchen and restaurant on the first floor. The revised plans include only one bar (one has been deleted), an enlarged kitchen and detailed seating layout, still all on the first floor. The restaurant bar shifted slightly east, still within the space designated as restaurant. 1.2 Expansion of the previously approved ground floor kitchen. 1.3 Additional kitchen exhaust shaft (underside Level 2 up to roof). 1.4 Removal of previously approved ground floor bar in historic building. 1.5 Modified restrooms. The overall restroom fixture count remains unchanged. 1.6 Added a temporary retractable glazed roof system within the buildings open courtyard. This structure is a 3-season installation, not supported by the existing building. 1.7 Revised pantry service areas on penthouse level. 1.8 Added portable outdoor bar on penthouse level and operable storefront windows. 1.9 Reduced fire resistance rating requirement for northern historic building intumescent paint at primary floor/ roof structure in accordance with IBC 403.2.1. Engineering Judgement provided by SLS is included in the supporting documents and referenced in drawings. 1.10 During work, historic beams and columns were discovered in the historic core. These will be protected via spray applied fireproofing to achieve a one-hour fire rating for beams and two-hour fire rating for columns per IBC 403.2.1 1.11 Miscellaneous receptacle relocations on guestroom floors. The Gross Area affected is 11,750 SF SIDEWALK CAFE IS NOT UNDER THIS PERMIT.
- Current status
- expired
- Source status
- EXPIRED
- First seen (no changes since)
- May 19, 2026 · 00:16 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Jan 19, 2026E2604603MEP Electrical · Issued
- Nov 25, 2024FB2500041Other · Issued
- Nov 22, 2024This permitAlteration Commercial · Expired
- Nov 20, 2024AH2500249Other · Expired
- Oct 25, 2024AH2500117Other · Expired
- Oct 9, 2024SG2400400Sign · Finaled
- Sep 18, 2024AH2401025Other · Expired
- Sep 13, 2024P2410114MEP Plumbing · Finaled
- Aug 14, 2024AH2400966Other · Expired
- Aug 13, 2024SG2400316Sign · Finaled
- Jul 3, 2024SG2400215Sign · Finaled
- Jul 3, 2024SG2400214Sign · Expired
- Jun 20, 2024AH2400853Other · Expired
- Jun 13, 2024AH2400814Other · Expired
- May 8, 2024AH2400692Other · Expired
- Apr 4, 2024AH2400585Other · Expired
- Mar 12, 2024P2404712MEP Plumbing · Finaled
- Feb 12, 2024B2401155Alteration Commercial · Expired
- Jan 31, 2024AH2400378Other · Expired
- Jan 10, 2024MVQ2400099Alteration Commercial · Expired
- Jan 10, 2024AH2400325Other · Expired
- Dec 8, 2023E2402528MEP Electrical · Finaled
- Nov 20, 2023E2401891MEP Electrical · Finaled
- Oct 25, 2023AH2400054Other · Expired
- Oct 5, 2023AH2400027Other · Expired
- Oct 5, 2023AH2400001Other · Expired
- Sep 15, 2023AH2301090Other · Expired
- Aug 14, 2023AH2301031Other · Expired
- Jul 19, 2023AH2300989Other · Expired
- Jun 28, 2023AH2300818Other · Expired
- May 24, 2023AH2300774Other · Expired
Full permit history at this parcel · as of Aug 12, 2026.
Developer details
- Permit #
- B2401755
- Canonical ID
- 243:B2401755
- Source permit ID
- B2401755