Permit Record

Alteration Commercial

5205 11th St NE, Washington, DC 20011

ClassificationAlteration
Reliable valueNot in source
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Null Null;
Owner
Street, Chrstopher L
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
3752-0003
Climate zone (IECC)
4A
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
ALTERATION AND REPAIR
Geocode & dates
Coordinates
38.9548, -76.9913
Geocode confidence
95%
Geocode source
Not in source
Issued
Jul 9, 2026
Applied
Not in source
Work class
Residential
Description
Source description

NEW PAVER PATIO INSTALLATIONPatio Dimensions: 11 X 15 + 7 X 13 + 24' FL X 21 FEET = 760 SF Patio Location: BACK YARD Scope of Work:Provide labor, materials, and equipment to perform the following tasks:NEW PATIO:Build a new Paver Patio using the specified Paver type as described below:Paver Brand: BELGARD Patio Design: RECTAGULAR WITH CURB DESING TO INSTALL A FLOWER BED Paver Type: DIMENSION 12 Paver Color: COSTUMER CHOICE Paver Pattern: RANDOM Border: CHARCOAL 6 X 9 Patio Elevation: AS THE EXISTING CONCRETE PATIO Note: The patio must be constructed with a proper slope to facilitate rainwater drainage.PROCEDURE FOR PAVER INSTALLATION Excavate all areas as the contract/design , specify approx. _6 in depth. Soil will be compact with a 9000 PSI Plate Compactor.Geotextile fabric will be Installed to prevent migration between soils and base materials.proper base material and compact in 3 IN to 4 IN lift, To achieve maximum compaction.approx. 2% grade pitch to divert water.1 IN Screed Concrete sand bed will be install over Cr6 gravel base All Pavers will be Install as the contract/deign specify Pattern, Border & Color Edge restraint will be install on all paver edges, with 10 IN spikes. All Pavers will be compact with plate compact to create interlocking concrete Polymeric Sand will be install on all paver joints and re-compact All outer edges will be graded property for Mulch or Grass Seed as needed. All work area will be cleaned of debris for safety on a daily basis.

Status
Current status
issued
Source status
PERMIT ISSUED
Provenance
First seen by PermitCore
Jul 13, 2026 · 10:31 UTC
Last seen
Aug 14, 2026 · 10:15 UTC
Last changed
Aug 14, 2026 · 10:15 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

3 permits at this parcel (parcel 3752-0003) · Dec 11, 2009Jul 9, 2026

  1. Jul 9, 2026This permitAlteration Commercial · Issued
  2. Jun 20, 2024B2407460Alteration Commercial · Expired
  3. Dec 11, 2009P1001262MEP Plumbing · Expired

Full permit history at this parcel · as of Aug 14, 2026.

Developer details
Permit #
B2606015
Canonical ID
243:B2606015
Source permit ID
B2606015
Browse Washington, DC permits in the Market Explorer →Pull this permit via /v1/permits →