Permit Record

Residential

3300 White Ave Baltimore Maryland 21214-2346, Baltimore, MD

Classification1-15
Reliable value$3,000
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Not in source
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
5683 003
Climate zone (IECC)
4A
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
Not in source
Building subtype
1-15
Geocode & dates
Coordinates
39.3521, -76.5537
Geocode confidence
100%
Geocode source
geocodio
Issued
Dec 5, 2024
Applied
Not in source
Work class
Residential
Description
Source description

SCOPE OF WORK - BUILD EXTERIOR STAIRS TO GIVE ACCESS TO THE 2ND UNIT. ALL LANDINGS ARE MADE OF 2X8 P.T. AS JOIST, BAND BOARDS & ATTACHED TO THE HOUSE AS STATED BELOW. LEDGER BOARD BOLTED WITH STRUCTUAL SCREW THRU SHEATHING TO STUDS WITH SPAX 1/2 IN. X 8 IN. EXTERIOR HEX HEAD STRUCTURAL WOOD LAG SCREWS POWERLAGS HEX EACH SCREWED 16" O.C AND STAGGERED. LANDING FLOOR JOIST PLACED 16" O.C. AND EACH SUPPORTED WITH 2X8 JOIST HANGERS ON BOTH ENDS. FLOORS MADE OF 5/4 IN. X 6 IN. X 16 FT. GROUND CONTACT PRESSURE-TREATED PREMIUM SOUTHERN YELLOW PINE DECKING BOARDS. (2) BAND BOARD FOR EACH LANDING WILL ACT AS A BEAM AND SIT ON A 6 X 6 P.T. POST SUPPORT LUMBER NOTCHED AND ANCHORED WITH (2) 1/2" LAG BOLTS. EACH POST SUPPORT WILL SIT ON 14" SUNOTUBE WITH 48" DEPTH AND ANCHORED USING GALVANIZED STANDOFF COLUMN BASE FOR 6X6 NOMINAL LUMBER AND MANUFACTURED SPECIFIED BOLTS. GROUND LANDING WILL BE CONSTRUCTED OF 4FT X 4FT X 8" CONCRETE STAIRS TO AND FROM EACH LANDING WILL BE CONSTRUCTED WITH (2) 2X12 P.T. AS STRINGERS WITH 6" RISERS AND 2 IN. X 12 IN. X 16 FT. PRIME GROUND CONTACT PRESSURE-TREATED LUMBER AS TREADS. RAILINGS WILL BE 36" HIGH AND MADE OF WHITE POLYCOMPOSITE VINYL. AS PER PLANS AND AS PER CODE.

Status
Current status
issued
Source status
Issued
Expired
Jun 5, 2025
Provenance
First seen by PermitCore
May 20, 2026 · 02:41 UTC
Last seen
Jun 25, 2026 · 01:06 UTC
Last changed
Jun 25, 2026 · 01:06 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel
Developer details
Permit #
baltimore_COM2024-80978
Canonical ID
337:baltimore_COM2024-80978
Source permit ID
baltimore_COM2024-80978
Browse Baltimore permits in the Market Explorer →Pull this permit via /v1/permits →