MEP Electrical
3419 Bancroft Rd, Baltimore, MD
- Contractor
- Not in source
- Applicant
- Not in source
- Owner
- Not in source
- Architect
- Not in source
- Engineer
- Not in source
- Contractor license
- Not in source
- Building class
- Not in source
- Zoning district
- Not in source
- Lot area
- Not in source
- Year built
- Not in source
- Units (total)
- Not in source
- Units (residential)
- Not in source
- Units (commercial)
- Not in source
- Floor area
- Not in source
- Parcel APN
- 4339 010
- Climate zone (IECC)
- 4A
- Roof area (est.)
- Not derivable — no building-size signal for this permit
- HVAC tonnage (est.)
- Not derivable — no building-size signal for this permit
- Building type
- R
- Building subtype
- Single Family Dwelling
- Coordinates
- 39.3622, -76.6966
- Geocode confidence
- 100%
- Geocode source
- geocodio
- Issued
- Feb 24, 2026
- Applied
- Not in source
- Work class
- Residential
Source description
General Electric Work: (Throughout the property) - Includes brand-new electrical wiring, electrical panel Homeline 200 Amp 40-Space - New switches and outlets in kitchen, living room, dining room, bathroom, and bedrooms all in compliance with Baltimore code. - Ceiling lights and other lighting fixtures are excluded from this project due to budget limitations. 1st floor: - Kitchen: 1 switch and 4 outlets - Bathroom: 1 switch 1 outlet - Dining room: 1 switch 3 outlets - Living room: 2 switches and 7 outlets - Sitting room: 1 switch 3 outlets 2nd floor: - 1st room: 1 switch 3 outlets - 2nd room: 1 switch 2 outlets - 3rd room: 1 switch 2 outlets - 1st bathroom: 1 switch 1 outlets - 2nd bathroom: 1 switch 1 outlets Attic 3rd floor: - 1st room: 1 switch 2 outlets - 2nd room: 1 switch 3 outlets - 3rd room: 1 switch 2 outlets - 1st bathroom: 1 switch 1 outlet Basement: - 3 switches and 5 outlets Total: 18 switches and 41 outlets - Repair, patch, and apply coat finish to the openings made for electrical wiring - Paint over the openings - The paint will be matched to the existing paint on the walls Plumbing: (Basement) - Repair the drain, waste, and vent system Replace damaged metal tubing with PVC using three Y-connectors, and reconnect all existing tubing, including the vent system The following pipe measurements will be used: - 90 inches of 3 inch pipe - 212 inches of 5 inch pipe - Three 5 inch Y connectors - One 3 inch T connector - 1 toilet pipe plug
- Current status
- issued
- Source status
- Issued
- Expired
- Aug 23, 2026
- First seen by PermitCore
- May 20, 2026 · 02:35 UTC
- Last seen
- Jun 25, 2026 · 00:50 UTC
- Last changed
- Jun 25, 2026 · 00:50 UTC
0 of 12 data-quality rules flagged anything on this permit.
Checks not flagged
- Geocode out of bounds
- Geocode is sentinel
- Issued date in the future
- Issued date parse bug
- Issued date is placeholder
- Commercial units is placeholder
- Residential units out of bounds
- Residential units is placeholder
- Total units out of bounds
- Total units is placeholder
- Valuation out of bounds
- Valuation is placeholder
- Feb 24, 2026This permitMEP Electrical · Issued$25,000
- Jul 25, 2025baltimore_BRCM-25-009170Other · Issued$13,000
Full permit history at this parcel · as of Jul 8, 2026.
Developer details
- Permit #
- baltimore_BRCM-26-003664
- Canonical ID
- 337:baltimore_BRCM-26-003664
- Source permit ID
- baltimore_BRCM-26-003664