Permit Record

MEP Electrical

3419 Bancroft Rd, Baltimore, MD

ClassificationSingle Family DwellingResidential MEP
Reliable value$25,000
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Not in source
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
4339 010
Climate zone (IECC)
4A
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
R
Building subtype
Single Family Dwelling
Geocode & dates
Coordinates
39.3622, -76.6966
Geocode confidence
100%
Geocode source
geocodio
Issued
Feb 24, 2026
Applied
Not in source
Work class
Residential
Description
Source description

General Electric Work: (Throughout the property) - Includes brand-new electrical wiring, electrical panel Homeline 200 Amp 40-Space - New switches and outlets in kitchen, living room, dining room, bathroom, and bedrooms all in compliance with Baltimore code. - Ceiling lights and other lighting fixtures are excluded from this project due to budget limitations. 1st floor: - Kitchen: 1 switch and 4 outlets - Bathroom: 1 switch 1 outlet - Dining room: 1 switch 3 outlets - Living room: 2 switches and 7 outlets - Sitting room: 1 switch 3 outlets 2nd floor: - 1st room: 1 switch 3 outlets - 2nd room: 1 switch 2 outlets - 3rd room: 1 switch 2 outlets - 1st bathroom: 1 switch 1 outlets - 2nd bathroom: 1 switch 1 outlets Attic 3rd floor: - 1st room: 1 switch 2 outlets - 2nd room: 1 switch 3 outlets - 3rd room: 1 switch 2 outlets - 1st bathroom: 1 switch 1 outlet Basement: - 3 switches and 5 outlets Total: 18 switches and 41 outlets - Repair, patch, and apply coat finish to the openings made for electrical wiring - Paint over the openings - The paint will be matched to the existing paint on the walls Plumbing: (Basement) - Repair the drain, waste, and vent system Replace damaged metal tubing with PVC using three Y-connectors, and reconnect all existing tubing, including the vent system The following pipe measurements will be used: - 90 inches of 3 inch pipe - 212 inches of 5 inch pipe - Three 5 inch Y connectors - One 3 inch T connector - 1 toilet pipe plug

Status
Current status
issued
Source status
Issued
Expired
Aug 23, 2026
Provenance
First seen by PermitCore
May 20, 2026 · 02:35 UTC
Last seen
Jun 25, 2026 · 00:50 UTC
Last changed
Jun 25, 2026 · 00:50 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

2 permits at this parcel (parcel 4339 010) · Jul 25, 2025Feb 24, 2026

  1. Feb 24, 2026This permitMEP Electrical · Issued$25,000
  2. Jul 25, 2025baltimore_BRCM-25-009170Other · Issued$13,000

Full permit history at this parcel · as of Jul 8, 2026.

Developer details
Permit #
baltimore_BRCM-26-003664
Canonical ID
337:baltimore_BRCM-26-003664
Source permit ID
baltimore_BRCM-26-003664
Browse Baltimore permits in the Market Explorer →Pull this permit via /v1/permits →