Permit Record

MEP Mechanical HVAC

1421 McCulloh St, Baltimore, MD

ClassificationDwelling: RowhouseResidential MEP
Reliable value$10,000
ContractorNot in source
Permit record
Parties
Contractor
Not in source
Applicant
Not in source
Owner
Not in source
Architect
Not in source
Engineer
Not in source
Contractor license
Not in source
Building & lot · PLUTO
Building class
Not in source
Zoning district
Not in source
Lot area
Not in source
Year built
Not in source
Units (total)
Not in source
Units (residential)
Not in source
Units (commercial)
Not in source
Floor area
Not in source
Parcel & enrichment
Parcel APN
0378 021
Climate zone (IECC)
4A
Roof area (est.)
Not derivable — no building-size signal for this permit
HVAC tonnage (est.)
Not derivable — no building-size signal for this permit
Building type
R
Building subtype
Dwelling: Rowhouse
Geocode & dates
Coordinates
39.3039, -76.6292
Geocode confidence
100%
Geocode source
geocodio
Issued
Apr 23, 2026
Applied
Not in source
Work class
Residential
Description
Source description

Interior work: Framing to create new partition walls, drywall, trim, subfloor, insulations (R21 walls/R49ceilings), interior doors, Complete the following work on front facade: Clean the stone and brick masonry with the gentlest means as possible, such as low pressure water spray (100-400 psi), mild detergent and natural-bristle hand brushes. Repoint mortar where open, deteriorated and too hard with lime based mortar to match historic mortar. Mortar to be same color (when dry), texture, joint size, profile, and hardness as historic mortar. Remove all windows and install two 2/4 double hung windows with Baltimore bullnose trim, at the 1st floor. At the 2nd and 3rd floors, install six 2/2 double hung windows with Baltimore bullnose trim. Doors and windows to fit in existing masonry openings with no additional framing or filler. Install one black lantern sconce, mailbox, security camera and doorbell adjacent to the main entryway. Latern, mailbox, doorbell and camera to be installed using mortar joint only and not bricks. Install one black wrought iron handrail to match the architectural detailing of historic railings at adjacent properties. Railings to be installed within mortar joints and concrete sidewalk only and not historic marble stoop. At the basement, remove the Bilco door and install two black wrought iron safety railings. At the buildings roofline, repair the cornice with new wood and wood epoxies to match existing. Scrape, prime and paint the security bars, door, door trim, transom trim, window, and window trim with Sherman Williams SW6259 - Triscorn Black.  Complete the following work on the rear elevation: remove all windows installed without proper permits and CHAP approval. At the basement, 1st, 2nd and 3rd floors, install eight 1/1 white double hung windows. At the 1st, 2nd and 3rd floors, install cementitious smooth lap horizontal siding in Light Mist color. At the 2nd and 3rd floors, replace the two left most windows with two 6 panel metal doors. New doors and windows to fit new wood framed openings with no additional framing or filler. Doors and windows at the rear to have fiber cement trim. At the 1st, 2nd and 3rd floors, construct one (18’ 7 1/2” x 11’ 8”) 3 story pressure treated wood decking structure and one pressure treated wood staircase at the 1st floor to grade. New decking structure to have pressure treated wood decking boards, rectangular vertical spindles and handrails. Install one black lantern sconce adjacent to the door. Install one floodlight with a motion sensor at each floor. At the 1st floor, install one wall mounted security camera at the left side of the wall. In the rear yard, install one 6’H vertically paneled pressure treated wood fence with a pedestrian gate at the alley running from the rear wall along the side property lines of the rear alley. At the roofline, install black K styled aluminum gutters and downspouts. At grade, install one staircase at basement entryway. Complete the following work on the roof: install one modified bitumen rolled rubber roof membrane. Install two hvac condensed units as per plans. New condenser units not be highly visible from the street, all work will be done as per code,Approved For Work only subject to the permitted uses and regulations under the provisions of the Zoning Ordinance.

Status
Current status
issued
Source status
Issued
Expired
Oct 20, 2026
Provenance
First seen by PermitCore
May 20, 2026 · 02:36 UTC
Last seen
Jun 25, 2026 · 00:50 UTC
Last changed
Jun 25, 2026 · 00:50 UTC
Data-quality checks0 of 12 flagged

0 of 12 data-quality rules flagged anything on this permit.

Checks not flagged

  • Geocode out of bounds
  • Geocode is sentinel
  • Issued date in the future
  • Issued date parse bug
  • Issued date is placeholder
  • Commercial units is placeholder
  • Residential units out of bounds
  • Residential units is placeholder
  • Total units out of bounds
  • Total units is placeholder
  • Valuation out of bounds
  • Valuation is placeholder
Project timeline at this parcel

3 permits at this parcel (parcel 0378 021) · Jun 3, 2019Apr 23, 2026

  1. Apr 23, 2026This permitMEP Mechanical HVAC · Issued$10,000
  2. Jun 1, 2020baltimore_COM2019-86823Alteration Residential · Issued$50,000
  3. Jun 3, 2019baltimore_COM2019-66244Demolition · Issued$5,000

Full permit history at this parcel · as of Jul 8, 2026.

Developer details
Permit #
baltimore_BRCM-26-006886
Canonical ID
337:baltimore_BRCM-26-006886
Source permit ID
baltimore_BRCM-26-006886
Browse Baltimore permits in the Market Explorer →Pull this permit via /v1/permits →